MOXA ICF-1150I-M-SC Serial-to-Fiber Converter
3-way communication: RS-232, RS-422/485, and fiber
Rotary switch to change the pull high/low resistor value
Extends RS-232/422/485 transmission up to 40 km with single-mode or 5 km with multi-mode
-40 to 85°C wide-temperature range models available
C1D2, ATEX, and IECEx certified for harsh industrial environments
Serial Interface
| No. of Ports | 2 | 
| Serial Standards | RS-232RS-422RS-485 | 
| Baudrate | 50 bps to 921.6 kbps (supports non-standard baudrates) | 
| Flow Control | ADDC (automatic data direction control) for RS-485 | 
| Connector | DB9 female for RS-232 interface5-pin terminal block for RS-422/485 interfaceFiber ports for RS-232/422/485 interface | 
| Isolation | 2 kV (I models) | 
Serial Signals
| RS-232 | TxD, RxD, GND | 
| RS-422 | Tx+, Tx-, Rx+, Rx-, GND | 
| RS-485-4w | Tx+, Tx-, Rx+, Rx-, GND | 
| RS-485-2w | Data+, Data-, GND | 
Power Parameters
| Input Current | ICF-1150 Series: 264 mA@12to 48 VDC ICF-1150I Series: 300 mA@12to 48 VDC | 
| Input Voltage | 12to48 VDC | 
| No. of Power Inputs | 1 | 
| Overload Current Protection | Supported | 
| Power Connector | Terminal block | 
| Power Consumption | ICF-1150 Series: 264 mA@12to 48 VDC ICF-1150I Series: 300 mA@12to 48 VDC | 
Physical Characteristics
| Housing | Metal | 
| IP Rating | IP30 | 
| Dimensions | 30.3 x70 x115 mm (1.19x 2.76 x 4.53 in) | 
| Weight | 330 g (0.73 lb) | 
| Installation | DIN-rail mounting | 
Environmental Limits
| Operating Temperature | Standard Models: 0 to 60°C (32 to 140°F) Wide Temp. Models: -40 to 85°C (-40 to 185°F) | 
| Storage Temperature (package included) | -40 to 85°C (-40 to185°F) | 
| Ambient Relative Humidity | 5 to 95% (non-condensing) | 
MOXA ICF-1150I-M-SC Available Models
| Model Name | Isolation | Operating Temp. | Fiber Module Type | IECEx Supported | 
| ICF-1150-M-ST | - | 0 to 60°C | Multi-mode ST | - | 
| ICF-1150-M-SC | - | 0 to 60°C | Multi-mode SC | - | 
| ICF-1150-S-ST | - | 0 to 60°C | Single-mode ST | - | 
| ICF-1150-S-SC | - | 0 to 60°C | Single-mode SC | - | 
| ICF-1150-M-ST-T | - | -40 to 85°C | Multi-mode ST | - | 
| ICF-1150-M-SC-T | - | -40 to 85°C | Multi-mode SC | - | 
| ICF-1150-S-ST-T | - | -40 to 85°C | Single-mode ST | - | 
| ICF-1150-S-SC-T | - | -40 to 85°C | Single-mode SC | - | 
| ICF-1150I-M-ST | 2kV | 0 to 60°C | Multi-mode ST | - | 
| ICF-1150I-M-SC | 2kV | 0 to 60°C | Multi-mode SC | - | 
| ICF-1150I-S-ST | 2kV | 0 to 60°C | Single-mode ST | - | 
| ICF-1150I-S-SC | 2kV | 0 to 60°C | Single-mode SC | - | 
| ICF-1150I-M-ST-T | 2kV | -40 to 85°C | Multi-mode ST | - | 
| ICF-1150I-M-SC-T | 2kV | -40 to 85°C | Multi-mode SC | - | 
| ICF-1150I-S-ST-T | 2kV | -40 to 85°C | Single-mode ST | - | 
| ICF-1150I-S-SC-T | 2kV | -40 to 85°C | Single-mode SC | - | 
| ICF-1150-M-ST-IEX | - | 0to 60°C | Multi-mode ST | / | 
| ICF-1150-M-SC-IEX | - | 0to 60°C | Multi-mode SC | / | 
| ICF-1150-S-ST-IEX | - | 0to 60°C | Single-mode ST | / | 
| ICF-1150-S-SC-IEX | - | 0to 60°C | Single-mode SC | / | 
| ICF-1150-M-ST-T-IEX | - | -40 to 85°C | Multi-mode ST | / | 
| ICF-1150-M-SC-T-IEX | - | -40 to 85°C | Multi-mode SC | / | 
| ICF-1150-S-ST-T-IEX | - | -40 to 85°C | Single-mode ST | / | 
| ICF-1150-S-SC-T-IEX | - | -40 to 85°C | Single-mode SC | / | 
| ICF-1150I-M-ST-IEX | 2kV | 0to 60°C | Multi-mode ST | / | 
| ICF-1150I-M-SC-IEX | 2kV | 0to 60°C | Multi-mode SC | / | 
| ICF-1150I-S-ST-IEX | 2kV | 0to 60°C | Single-mode ST | / | 
| ICF-1150I-S-SC-IEX | 2kV | 0to 60°C | Single-mode SC | / | 
| ICF-1150I-M-ST-T-IEX | 2kV | -40 to 85°C | Multi-mode ST | / | 
| ICF-1150I-M-SC-T-IEX | 2kV | -40 to 85°C | Multi-mode SC | / | 
| ICF-1150I-S-ST-T-IEX | 2kV | -40 to 85°C | Single-mode ST | / | 
| ICF-1150I-S-SC-T-IEX | 2kV | -40 to 85°C | Single-mode SC | / | 