MOXA EDS-308-S-SC Ethernet switches provide an economical solution for your industrial Ethernet connections. These 8-port switches come with a built-in relay warning function that alerts network engineers when power failures or port breaks occur. In addition, the switches are designed for harsh industrial environments, such as the hazardous locations defined by the Class 1 Div. 2 and ATEX Zone 2 standards.

The switches comply with FCC, UL, and CE standards and support either a standard operating temperature range of -10 to 60°C or a wide operating temperature range of -40 to 75°C. All switches in the series undergo a 100% burn-in test to ensure that they fulfill the special needs of industrial automation control applications. The EDS-308 switches can be installed easily on a DIN rail or in a distribution box.


Product Detail

Product Tags

Features and Benefits

Relay output warning for power failure and port break alarm

Broadcast storm protection

-40 to 75°C operating temperature range (-T models)

Specifications

Ethernet Interface

10/100BaseT(X) Ports (RJ45 connector) EDS-308/308-T: 8EDS-308-M-SC/308-M-SC-T/308-S-SC/308-S-SC-T/308-S-SC-80:7EDS-308-MM-SC/308-MM-SC-T/308-MM-ST/308-MM-ST-T/308-SS-SC/308-SS-SC-T/ 308-SS-SC-80: 6All models support:Auto negotiation speed

Full/Half duplex mode

Auto MDI/MDI-X connection

100BaseFX Ports (multi-mode SC connector) EDS-308-M-SC: 1 EDS-308-M-SC-T: 1 EDS-308-MM-SC: 2 EDS-308-MM-SC-T: 2
100BaseFX Ports (multi-mode ST connector) EDS-308-MM-ST: 2 EDS-308-MM-ST-T: 2
100BaseFX Ports (single-mode SC connector) EDS-308-S-SC: 1 EDS-308-S-SC-T: 1 EDS-308-SS-SC: 2 EDS-308-SS-SC-T: 2
100BaseFX Ports (single-mode SC connector, 80km) EDS-308-S-SC-80: 1
EDS-308-SS-SC-80: 2
Standards IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3x for flow control

Power Parameters

Input Current EDS-308/308-T: 0.07 A@24 VDCEDS-308-M-SC/S-SC Series, 308-S-SC-80: 0.12A@ 24 VDCEDS-308-MM-SC/MM-ST/SS-SC Series, 308-SS-SC-80: 0.15A@ 24 VDC
Connection 1 removable 6-contact terminal block(s)
Operating Voltage 9.6 to 60 VDC
Input Voltage Redundant dual inputs,12/24/48VDC
Reverse Polarity Protection Supported
Overload Current Protection Supported

Physical Characteristics

Housing Metal
IP Rating IP30
Dimensions 53.6 x135x105 mm (2.11 x 5.31 x 4.13 in)
Weight 790 g (1.75 lb)
Installation DIN-rail mounting, Wall mounting (with optional kit)

Environmental Limits

Operating Temperature Standard Models: -10 to 60°C (14to 140°F) Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature (package included) -40 to 85°C (-40 to185°F)
Ambient Relative Humidity 5 to 95% (non-condensing)

MOXA EDS-308-S-SC Available Models

Model 1 MOXA EDS-308
Model 2 MOXA EDS-308-MM-SC
Model 3 MOXA EDS-308-MM-ST
Model 4 MOXA EDS-308-M-SC
Model 5 MOXA EDS-308-S-SC
Model 6 MOXA EDS-308-S-SC-80
Model 7 MOXA EDS-308-SS-SC
Model 8 MOXA EDS-308-SS-SC-80
Model 9 MOXA EDS-308-MM-SC-T
Model 10 MOXA EDS-308-MM-ST-T
Model 11 MOXA EDS-308-M-SC-T
Model 12 MOXA EDS-308-S-SC-T
Model 13 MOXA EDS-308-SS-SC-T
Model 14 MOXA EDS-308-T

  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • MOXA NPort 5250AI-M12 2-port RS-232/422/485 device server

      MOXA NPort 5250AI-M12 2-port RS-232/422/485 dev...

      Introduction The NPort® 5000AI-M12 serial device servers are designed to make serial devices network-ready in an instant, and provide direct access to serial devices from anywhere on the network. Moreover, the NPort 5000AI-M12 is compliant with EN 50121-4 and all mandatory sections of EN 50155, covering operating temperature, power input voltage, surge, ESD, and vibration, making them suitable for rolling stock and wayside app...

    • MOXA TCF-142-M-ST Industrial Serial-to-Fiber Converter

      MOXA TCF-142-M-ST Industrial Serial-to-Fiber Co...

      Features and Benefits Ring and point-to-point transmission Extends RS-232/422/485 transmission up to 40 km with single-mode (TCF- 142-S) or 5 km with multi-mode (TCF-142-M) Decreases signal interference Protects against electrical interference and chemical corrosion Supports baudrates up to 921.6 kbps Wide-temperature models available for -40 to 75°C environments ...

    • MOXA A-ADP-RJ458P-DB9F-ABC01 Connector

      MOXA A-ADP-RJ458P-DB9F-ABC01 Connector

      Moxa's cables   Moxa's cables come in a variety of lengths with multiple pin options to ensure compatibility for a wide range of applications. Moxa's connectors include a selection of pin and code types with high IP ratings to ensure suitability for industrial environments.   Specifications   Physical Characteristics Description TB-M9: DB9 ...

    • MOXA EDS-316-MM-SC 16-port Unmanaged Industrial Ethernet Switch

      MOXA EDS-316-MM-SC 16-port Unmanaged Industrial...

      Features and Benefits Relay output warning for power failure and port break alarm Broadcast storm protection -40 to 75°C operating temperature range (-T models) Specifications Ethernet Interface 10/100BaseT(X) Ports (RJ45 connector) EDS-316 Series: 16 EDS-316-MM-SC/MM-ST/MS-SC/SS-SC Series, EDS-316-SS-SC-80: 14 EDS-316-M-...

    • MOXA NPort IA-5250 Industrial Automation Serial Device Server

      MOXA NPort IA-5250 Industrial Automation Serial...

      Features and Benefits Socket modes: TCP server, TCP client, UDP ADDC (Automatic Data Direction Control) for 2-wire and 4-wire RS-485 Cascading Ethernet ports for easy wiring (applies only to RJ45 connectors) Redundant DC power inputs Warnings and alerts by relay output and email 10/100BaseTX (RJ45) or 100BaseFX (single mode or multi-mode with SC connector) IP30-rated housing   ...

    • MOXA EDS-316 16-port unmanaged Ethernet switch

      MOXA EDS-316 16-port unmanaged Ethernet switch

      Introduction The EDS-316 Ethernet switches provide an economical solution for your industrial Ethernet connections. These 16-port switches come with a built-in relay warning function that alerts network engineers when power failures or port breaks occur. In addition, the switches are designed for harsh industrial environments, such as the hazardous locations defined by the Class 1 Div. 2 and ATEX Zone 2 standards....