• head_banner_01

SIEMENS 6ES7392-1BM01-0AA0 SIMATIC S7-300 Front Connector For Signal Modules

Short Description:

SIEMENS 6ES7392-1BM01-0AA0: SIMATIC S7-300, Front connector for signal modules with spring-loaded contacts, 40-pole.


  • :
  • Product Detail

    Product Tags

    SIEMENS 6ES7392-1BM01-0AA0

     

    Product
    Article Number (Market Facing Number) 6ES7392-1BM01-0AA0
    Product Description SIMATIC S7-300, Front connector for signal modules with spring-loaded contacts, 40-pole
    Product family Front connectors
    Product Lifecycle (PLM) PM300:Active Product
    PLM Effective Date Product phase-out since: 01.10.2023
    Delivery information
    Export Control Regulations AL : N / ECCN : N
    Standard lead time ex-works 50 Day/Days
    Net Weight (kg) 0,095 Kg
    Packaging Dimension 5,10 x 13,10 x 3,40
    Package size unit of measure CM
    Quantity Unit 1 Piece
    Packaging Quantity 1
    Additional Product Information
    EAN 4025515062004
    UPC 662643169775
    Commodity Code 85366990
    LKZ_FDB/ CatalogID ST73
    Product Group 4033
    Group Code R151
    Country of origin Germany

     

    SIEMENS Front connectors

     

    Overview
    For the simple and user-friendly connection of sensors and actuators to the S7-300 I/O modules
    For maintaining the wiring when replacing modules ("permanent wiring")
    With mechanical coding to avoid errors when replacing modules

    Application
    The front connector permits the simple and user-friendly connection of the sensors and actuators to the I/O modules.

    Use of the front connector:

    Digital and analog I/O modules
    S7-300 compact CPUs
    It comes in 20-pin and 40-pin variants.
    Design
    The front connector is plugged onto the module and covered by the front door. When replacing a module, only the front connector is disconnected, the time-intensive replacement of all wires is not necessary. In order to avoid errors when replacing modules, the front connector is coded mechanically when first plugged in. Then, it only fits in to the modules of the same type. This avoids, for example, an AC 230 V input signal accidentally being plugged into the DC 24 V module.

    In addition, the plugs have a "pre-engagement position". This is where the plug is snapped onto the module before electrical contact is made. The connector clamps onto the module and can then easily be wired ("third hand"). After the wiring work, the connector is inserted further so that it makes contact.

    The front connector contains:

    Contacts for the wiring connection.
    Strain relief for the wires.
    Reset key for resetting the front connector when replacing the module.
    Intake for coding element attachment. There are two coding elements on the modules with attachment. The attachments lock in when the front connector is connected for the first time.
    The 40-pin front connector also comes with a locking screw for attaching and loosening the connector when replacing the module.

    The front connectors are available for the following connection methods:

    Screw terminals
    Spring-loaded terminals


  • Previous:
  • Next:

  • Write your message here and send it to us

    Related products

    • Weidmuller PRO INSTA 96W 48V 2A 2580270000 Switch-mode Power Supply

      Weidmuller PRO INSTA 96W 48V 2A 2580270000 Swit...

      General ordering data   Version Power supply, switch-mode power supply unit, 48 V Order No. 2580270000 Type PRO INSTA 96W 48V 2A GTIN (EAN) 4050118591002 Qty. 1 pc(s). Dimensions and weights   Depth 60 mm Depth (inches) 2.362 inch Height 90 mm Height (inches) 3.543 inch Width 90 mm Width (inches) 3.543 inch Net weight 361 g ...

    • MOXA NPort 6150 Secure Terminal Server

      MOXA NPort 6150 Secure Terminal Server

      Features and Benefits Secure operation modes for Real COM, TCP Server, TCP Client, Pair Connection, Terminal, and Reverse Terminal Supports nonstandard baudrates with high precision NPort 6250: Choice of network medium: 10/100BaseT(X) or 100BaseFX Enhanced remote configuration with HTTPS and SSH Port buffers for storing serial data when the Ethernet is offline Supports IPv6 Generic serial commands supported in Com...

    • Weidmuller A3C 1.5 PE 1552670000 Terminal

      Weidmuller A3C 1.5 PE 1552670000 Terminal

      Weidmuller’s A series terminal blocks characters Spring connection with PUSH IN technology (A-Series) Time saving 1.Mounting foot makes unlatching the terminal block easy 2. Clear distinction made between all functional areas 3.Easier marking and wiring Space saving design 1.Slim design creates a large amount of space in the panel 2.High wiring density despite less space being required on the terminal rail Safety...

    • Hirschmann OZD Profi 12M G11 PRO Interface Converter

      Hirschmann OZD Profi 12M G11 PRO Interface Conv...

      Description   Product description Type: OZD Profi 12M G11 PRO Name: OZD Profi 12M G11 PRO Description: Interface converter electrical/optical for PROFIBUS-field bus networks; repeater function; for quartz glass FO Part Number: 943905221 Port type and quantity: 1 x optical: 2 sockets BFOC 2.5 (STR); 1 x electrical: Sub-D 9-pin, female, pin assignment according to EN 50170 part 1 Signal Type: PROFIBUS (DP-V0, DP-V1, DP-V2 und F...

    • SIEMENS 6ES72221HF320XB0 SIMATIC S7-1200 Digital Ouput SM 1222 Module PLC

      SIEMENS 6ES72221HF320XB0 SIMATIC S7-1200 Digita...

      SIEMENS SM 1222 digital output modules Technical specifications   Article number 6ES7222-1BF32-0XB0 6ES7222-1BH32-0XB0 6ES7222-1BH32-1XB0 6ES7222-1HF32-0XB0 6ES7222-1HH32-0XB0 6ES7222-1XF32-0XB0   Digital Output SM1222, 8 DO, 24V DC Digital Output SM1222, 16 DO, 24V DC Digital Output SM1222, 16DO, 24V DC sink Digital Output SM 1222, 8 DO, Relay Digital Output SM1222, 16 DO, Relay Digital Output SM 1222, 8 DO, Changeover Genera...

    • WAGO 750-303 Fieldbus Coupler PROFIBUS DP

      WAGO 750-303 Fieldbus Coupler PROFIBUS DP

      Description   This fieldbus coupler connects the WAGO I/O System as a slave to the PROFIBUS fieldbus. The fieldbus coupler detects all connected I/O modules and creates a local process image. This process image may include a mixed arrangement of analog (word-by-word data transfer) and digital (bit-by-bit data transfer) modules. The process image can be transferred via the PROFIBUS fieldbus to the memory of the control system. The local pr...