| Item number |
2900298 |
| Packing unit |
10 pc |
| Minimum order quantity |
1 pc |
| Product key |
CK623A |
| Catalog page |
Page 382 (C-5-2019) |
| GTIN |
4046356507370 |
| Weight per piece (including packing) |
70.7 g |
| Weight per piece (excluding packing) |
56.8 g |
| Customs tariff number |
85364190 |
| Country of origin |
DE |
| Item number |
2900298 |
Product description
| Coil side |
| Nominal input voltage UN |
24 V DC |
| Input voltage range |
20.2 V DC ... 33.6 V DC (20 °C) |
| Drive and function |
monostable |
| Drive (polarity) |
polarized |
| Typical input current at UN |
18 mA |
| Typical response time |
8 ms |
| Typical release time |
10 ms |
| Coil voltage |
24 V DC |
| Protective circuit |
Reverse polarity protection; Polarity protection diode |
| Surge protection; Freewheeling diode |
| Operating voltage display |
Yellow LED |
Output data
| Switching |
| Contact switching type |
1 N/O contact |
| Type of switch contact |
Single contact |
| Contact material |
AgSnO |
| Maximum switching voltage |
250 V AC/DC (The separating plate PLC-ATP should be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or ...FBST 500...) |
| Minimum switching voltage |
12 V (100 mA) |
| Limiting continuous current |
6 A |
| 10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged) |
| Maximum inrush current |
80 A (20 ms) |
| 130 A (peak, at capacitive load, 230 V AC, 24 μF) |
| Min. switching current |
100 mA (12 V) |
| Interrupting rating (ohmic load) max. |
144 W (at 24 V DC) |
| 58 W (at 48 V DC) |
| 48 W (at 60 V DC) |
| 50 W (at 110 V DC) |
| 80 W |
| 85 W (for 250˽V˽DC) |
| 1500 VA (for 250˽V˽AC) |
| Interrupting rating (ohmic load) max. bridged |
240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
| 2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.) |
| Switching capacity min. |
1200 mW |
| Switching capacity |
2 A (at 24 V, DC13) |
| 0.2 A (at 110 V, DC13) |
| 0.2 A (at 250 V, DC13) |
| 6 A (at 24 V, AC15) |
| 6 A (at 120 V, AC15) |
| 6 A (at 250 V, AC15) |