Product description 
| Type | GRS106-16TX/14SFP-2HV-3AUR (Product code: GRS106-6F8F16TSGGY9HHSE3AURXX.X.XX) | 
| Description | GREYHOUND 105/106 Series, Managed Industrial Switch, fanless design, 19" rack mount, according to IEEE 802.3, 6x1/2.5/10GE +8x1/2.5GE +16xGE Design | 
| Software Version | HiOS 9.4.01 | 
| Part Number | 942287016 | 
| Port type and quantity | 30 Ports in total, 6x GE/2.5GE/10GE SFP(+) slot + 8x GE/2.5GE SFP slot + 16x FE/GE TX ports | 
 
More Interfaces
| Power supply/signaling contact | Power supply input 1: IEC plug, Signal contact: 2 pin plug-in terminal block , Power supply input 2: IEC plug | 
| SD-card slot | 1 x SD card slot to connect the auto configuration adapter ACA31 | 
| USB-C | 1 x USB-C (client) for local management | 
 
Network size - length of cable
| Twisted pair (TP) | 0-100 m | 
| Single mode fiber (SM) 9/125 µm | see SFP modules | 
| Single mode fiber (LH) 9/125 µm (long haul transceiver) | see SFP modules | 
| Multimode fiber (MM) 50/125 µm | see SFP modules | 
| Multimode fiber (MM) 62.5/125 µm | see SFP modules | 
 
Network size - cascadibility
| Line - / star topology | any | 
 
Power requirements
| Operating Voltage | Power supply input 1: 110 - 240 VAC, 50 Hz - 60 Hz , Power supply input 2: 110 - 240 VAC, 50 Hz - 60 Hz | 
| Power consumption | Basic unit with one power supply max. 35W | 
| Power output in BTU (IT)/h | max. 120 | 
 
Ambient conditions
| Operating temperature | -10 - +60 | 
| Note | 1 013 941 | 
| Storage/transport temperature | -20 - +70 °C | 
| Relative humidity (non-condensing) | 5-90 % | 
 
Mechanical construction
| Dimensions (WxHxD) | 444 x 44 x 355 mm | 
| Weight | 5 kg estimated | 
| Mounting | Rack mount | 
| Protection class | IP30 | 
 
Mechanical stability
| IEC 60068-2-6 vibration | 3.5 mm, 5 Hz – 8.4 Hz, 10 cycles, 1 octave/min.; 1 g, 8.4 Hz-200 Hz, 10 cycles, 1 octave/min | 
| IEC 60068-2-27 shock | 15 g, 11 ms duration, 18 shocks | 
 
EMC interference immunity
| EN 61000-4-2 electrostatic discharge (ESD) | 6 kV contact discharge, 8 kV air discharge | 
| EN 61000-4-3 electromagnetic field | 20 V/m (800-1000 MHz), 10V/m (80-800 MHz ; 1000-6000 MHz); 1 kHz, 80% AM | 
| EN 61000-4-4 fast transients (burst) | 2 kV power line, 4 kV data line STP, 2 kV data line UTP | 
| EN 61000-4-5 surge voltage | power line: 2 kV (line/earth) and 1 kV (line/line); data line: 2 kV | 
| EN 61000-4-6 Conducted Immunity | 10 V (150 kHz - 80 MHz) | 
 
EMC emitted immunity
| EN 55032 | EN 55032 Class A | 
 
Approvals
| Basis Standard | CE, FCC, EN61131 | 
| Safety of information technology equipment | EN62368, cUL62368 | 
 
Hirschmann GRS 105 106 Series GREYHOUND Switch Available Models
GRS105-16TX/14SFP-2HV-3AUR
GRS105-24TX/6SFP-1HV-2A
GRS105-24TX/6SFP-2HV-2A
GRS105-24TX/6SFP-2HV-3AUR
GRS106-16TX/14SFP-1HV-2A
GRS106-16TX/14SFP-2HV-2A
GRS106-16TX/14SFP-2HV-3AUR
GRS106-24TX/6SFP-1HV-2A
GRS106-24TX/6SFP-2HV-2A
GRS106-24TX/6SFP-2HV-3AUR