Technical Specifications
Product description
Description |
Managed Industrial Switch for DIN Rail, fanless design Fast Ethernet Type |
Software Version |
HiOS 09.6.00 |
Port type and quantity |
20 Ports in total: 16x 10/100BASE TX / RJ45; 4x 100Mbit/s fiber ; 1. Uplink: 2 x SFP Slot (100 Mbit/s) ; 2. Uplink: 2 x SFP Slot (100 Mbit/s) |
More Interfaces
Power supply/signaling contact |
1 x plug-in terminal block, 6-pin |
Digital Input |
1 x plug-in terminal block, 2-pin |
Local Management and Device Replacement |
USB-C |
Network size - length of cable
Twisted pair (TP) |
0 - 100 m |
Single mode fiber (SM) 9/125 µm |
see SFP fiber modules see SFP fiber modules |
Single mode fiber (LH) 9/125 µm (long haul transceiver) |
see SFP fiber modules see SFP fiber modules |
Multimode fiber (MM) 50/125 µm |
see SFP fiber modules see SFP fiber modules |
Multimode fiber (MM)62.5/125 µm |
see SFP fiber modules see SFP fiber modules |
Network size - cascadibility
Line - / star topology |
any |
Power requirements
Operating Voltage |
2 x 12 VDC ... 24 VDC |
Power consumption |
15 W |
Power output in BTU (IT)/h |
51 |
Ambient conditions
MTBF (TelecordiaSR-332 Issue 3) @ 25°C |
2 972 379 h |
Operating temperature |
0-+60 |
Storage/transport temperature |
-40-+70 °C |
Relative humidity (non-condensing) |
1- 95 % |
Mechanical construction
Dimensions (WxHxD) |
109 mm x 138 mm x 115 mm |
Weight |
950 g |
Housing |
PC-ABS |
Mounting |
DIN Rail |
Protection class |
IP30 |
Mechanical stability
IEC 60068-2-6 vibration
|
5 Hz ... 8,4 Hz with 3,5 mm amplitude; 2 Hz ... 13,2 Hz with 1 mm amplitude; 8,4 Hz ... 200 Hz with 1 g; 13,2 Hz ... 100 Hz with 0,7 g |
IEC 60068-2-27 shock
|
15 g, 11 ms duration |
EMC interference immunity
EN 61000-4-2electrostatic discharge (ESD) |
6 kV contact discharge, 8 kV air discharge |
EN 61000-4-3electromagnetic field |
10 V/m (80-2000 MHz); 5 V/m (2000-2700 MHz); 3 V/m (5100-6000 MHz) |
EN 61000-4-4 fasttransients (burst) |
2 kV power line, 2 kV data line |
EN 61000-4-5 surge voltage |
power line: 2 kV (line/earth) and 1 kV (line/line); data line: 2 kV |
EN 61000-4-6Conducted Immunity |
10 V (150 kHz-80 MHz) |
EMC emitted immunity
EN 55022 |
EN 55032 Class A |
FCC CFR47 Part 15 |
FCC 47CFR Part 15, Class A |
Approvals
Basis Standard |
CE, FCC, EN61131, EN62368-1 |